Overdrive Mud Saver Dropped Object
An opportunity to review a recent ‘high potential’ incident where personnel were exposed within the drill floor red zone. A Mud Saver weighing 40kg dropped 14m following contact with the rim of a stationery liner joint.
The presentation included CCTV footage supported by a series of Causes and Recommendations. Key highlights included:
- Misalignment - Insufficient visibility of connection interface
- Operating at Improper Speed – no clearly defined speed limit
- Impaired visibility – impaired decision making
- Previous learnings not embedded
- Lack of two-way communication
- Poor equipment positioning – no remote-control option
- Human Performance (including task fixation, cognitive overload, memory gap, limited situational awareness, confusion etc)